The elevator got stuck! 1986 Thorvald Sætre trion elevators with unrealiable modern controllers

  • hace 6 años
A routine safety-stop test causes the right elevator to get stuck below the top floor during repositioning. I managed to escape myself by opening the door lock manually as it was within reach from inside the elevator car. After that i rode the left elevator normally without any safety-stop tests as i just couldnt take the risk of both elevators to get stuck. This little hospital only has these two elevators.\r
\r
Dont ever do cheap modernizations on old elevators - this sort of unreliability is what you will get.\r
\r
These elevators are located at Horten Legevakt (on-duty doctors). Its not really a hospital, more like a little local medical centre.\r
\r
The floor plan at 06:50 in the video shows a third elevator in the upper right corner - a small passenger elevator. I searched for it but found nothing. I think it has been removed many years ago.\r
\r
***** Elevator Info *****\r
Location: Harald Pedersens Gate 9, 3182 Horten, Norway\r
Brand: Thorvald Sætre\r
Year: 1986\r
Serial: 2259 (left) - 2260 (right)\r
Type: Trion - with VF mod.\r
Floors served: 5\r
Capacity: 1000 kg / 13 persons\r
\r
***** Video Info *****\r
Time of recording: 21. December new, 16:28\r
Camera: Nikon 1 J2\r
Editor: Cyberlink PowerDirector 12